Steam rising from your outdoor heat pump in cold, damp weather is almost always defrost mode. The unit briefly reverses itself to melt frost off its outdoor coil, which makes steam, a whoosh, and sometimes a few minutes of cooler air inside. It's normal unless the unit stays caked in ice for hours or the fan won't run.
Reviewed by Gresham Heating & Air Conditioning, Oregon CCB #202643 ·
If you’ve walked outside on a cold morning in Gresham and seen your heat pump puffing steam like it’s about to blow, you’re not alone. We get this call every winter. In almost every case the heat pump is doing exactly what it was built to do: running a defrost cycle.
Here’s what’s going on, why our weather makes it happen so often, and the few signs that mean it’s time to call.
Why does a heat pump need to defrost?
In heating mode, a heat pump pulls heat out of the outdoor air and moves it inside. To do that, the coil in the outdoor unit runs colder than the air around it. When the air is damp and near freezing, moisture in that air freezes onto the coil as frost.
A little frost is fine. A thick layer acts like a blanket and blocks the airflow the heat pump needs, so the system clears it on its own. That’s defrost mode.
What happens during a defrost cycle?
When the heat pump’s controls decide the coil needs clearing, it:
- Shifts the reversing valve. The heat pump briefly runs like an air conditioner, sending warm refrigerant to the outdoor coil. You may hear a loud whoosh when this happens.
- Stops the outdoor fan. With the fan off, heat stays on the coil and the frost melts faster. The unit can seem to go quiet.
- Makes steam. Meltwater on a warm coil turns to vapor in the cold air. That’s the “smoke” people see. It has no smell, and it goes away in a few minutes.
- Turns on backup heat. Most systems bring on electric heat strips, or the gas furnace on a dual fuel system, so the air coming out of your vents doesn’t go cold while the heat pump works on the outdoor coil.
- Switches back to heating. Another whoosh, the fan starts again, and normal heating picks back up.
Older heat pumps check for frost on a timer. Newer ones watch temperature sensors and only defrost when frost is actually building up, which saves energy.
Why do Gresham heat pumps defrost so often?
Our winters are the perfect recipe for frost. East county spends long stretches of the winter with temperatures in the 30s and low 40s and air that’s close to saturated: fog, drizzle and wet nights. That combination puts more frost on an outdoor coil than a colder, drier climate does.
Then there’s the east wind. When cold air pours out of the Columbia Gorge, homes in Troutdale, Wood Village, Fairview and Gresham get hit first, and if that wind brings freezing rain, it can coat an outdoor unit in a shell of ice. Defrost mode clears frost on the coil, but it isn’t designed to melt a solid glaze off the cabinet. That’s when the unit needs help. (Our guide to getting your HVAC ready for east wind and ice storms covers what to do before a storm.)
What can I safely check myself?
- Give it time. Wait 15 to 20 minutes after you see steam. Most defrost cycles are done well before that.
- Clear around the unit. Keep snow, ice and leaves at least a foot or two away from all sides so air can move and meltwater can drain.
- Look up. A gutter that drips or overflows onto the top of the unit can build ice faster than defrost can clear it. Fixing the gutter often fixes the problem.
- Check the filter inside. A clogged filter cuts airflow and makes the whole system work harder in cold weather.
- Don’t chip, scrape or pour boiling water. The aluminum fins and copper tubing are easy to damage, and a punctured coil means a refrigerant repair.
When should I call a pro?
Call us if you notice any of these:
- The outdoor unit stays encased in ice for hours, or ice is building on the top panel and fan grille.
- The outdoor fan won’t run at all in heating mode, even after defrost should be done.
- The unit defrosts constantly but never clears.
- You get cold air from your vents during every defrost cycle. That usually points to backup heat that isn’t coming on.
- Ice on the refrigerant lines running into the house, or ice on the indoor unit.
- Your energy bill jumps while the house struggles to stay warm.
If the unit is iced over, set your thermostat to emergency heat (often labeled EM HEAT or AUX) if it has that setting. That runs your backup heat alone and gives the outdoor unit a rest until we can look at it. Emergency heat costs more to run, so use it as a bridge, not a habit.
Is this something regular maintenance prevents?
Defrost itself is normal and can’t be “fixed.” What a maintenance visit does is catch the things that make defrost fail: a dirty outdoor coil, a weak defrost sensor or control board, low refrigerant, or a unit sitting too low where meltwater refreezes around it. We’d rather find those on a dry afternoon in October than on an icy night in January. See our heating and cooling maintenance page for how a visit works.
Need a hand with your heat pump?
If your heat pump is iced over, blowing cold air, or just acting strange this winter, call Gresham Heating and Air Conditioning at 503-667-7594 or book a repair online. No-heat calls are treated as urgent. We’ve been keeping east county families warm since 1992, and we service every brand of heat pump, from all-electric systems to dual fuel setups paired with a gas furnace.
Ready when you are
Book a repair, maintenance visit or estimate online, with arrival windows of 8am to 12pm or 1pm to 5pm. No heat or no cooling? Call and we treat it as urgent.
Common questions
How long should a heat pump defrost cycle last?
Usually a few minutes, and rarely more than about 15. If the outdoor unit is still covered in ice after it has had a chance to defrost, or it seems to defrost over and over without clearing, have it checked.
Is it normal for my heat pump to stop and make a loud whoosh?
Yes. The whoosh is the reversing valve shifting refrigerant flow at the start and end of defrost. The outdoor fan also stops during defrost, so the unit goes quiet and then steams.
Should I pour hot water on my frozen heat pump?
Don't chip at the ice or hit the unit, because the coil fins and refrigerant tubing bend and puncture easily. If the unit is encased in ice, switch the thermostat to emergency heat if you have it and call for service.
Why does my house feel cooler while the heat pump defrosts?
During defrost the heat pump is briefly moving heat out of the house to warm the outdoor coil. Most systems turn on backup heat, either electric heat strips or a gas furnace on a dual fuel system, so the air from your vents stays warm. If you get cold air every time, the backup heat may not be working.