Getting your HVAC ready for east wind and ice storms
By Gresham Heating and Air Conditioning · Published
Before an east wind cold snap or ice storm, change your filter, clear a foot or two around your outdoor unit, make sure gutters don't drip on it, and know where your emergency heat setting is. During the storm, don't chip ice off a heat pump. After an outage, restart the system once and call if it won't run.
When the east wind comes out of the Columbia Gorge, east county gets the coldest air in the metro, sometimes for days and sometimes with freezing rain. Before a cold snap or ice storm: change your filter, clear space around the outdoor unit, check that gutters don’t drip on it, and know where your emergency heat setting is. During the storm, don’t chip ice off a heat pump. After an outage, restart once, and call if it won’t run.
Here’s the longer version.
Why does the east wind hit east county so hard?
In winter, cold, dense air builds up east of the Cascades and pours west through the Gorge. Troutdale, Wood Village, Fairview, Corbett and Gresham sit right at the mouth, so the wind is strongest here. When warmer, wet air from the Pacific rides over that cold layer, rain falls through it and freezes on contact. That’s our freezing rain.
For a heating system, that means three things: long hours of hard running, ice on outdoor units, and a higher chance of power outages.
Before the storm: what can I do now?
- Change the filter. A clogged filter makes the system work harder exactly when it can least afford to.
- Clear around the outdoor unit. Keep a foot or two clear on all sides, and trim plants back. Air has to move through the coil, and meltwater has to drain.
- Check the gutters above it. A gutter that drips or overflows onto a heat pump builds ice faster than defrost can clear it.
- Find your emergency heat setting on a heat pump thermostat, so you’re not hunting for it at 2am.
- Test your carbon monoxide alarms, especially if you have gas appliances or plan to run a generator.
- Book maintenance early. A fall maintenance visit catches weak parts before a cold snap finds them.
If you have a generator, know what it can run. A gas or propane furnace needs only a little power for its blower and controls; a heat pump needs much more. Generators always run outdoors, well away from windows and doors.
During the storm: is ice on my heat pump normal?
Some frost is normal, and the heat pump clears it with defrost mode: steam, a whoosh, and a few quiet minutes. Freezing rain is different. It can glaze the whole cabinet in ice that defrost isn’t designed to melt.
- Don’t chip, scrape or pour boiling water on it. The fins and tubing bend and puncture easily, and a punctured coil is a refrigerant repair.
- Don’t cover a running unit. It needs airflow.
- If it’s encased in ice, switch to emergency heat if you have it and call us. Emergency heat runs your backup heat only, which costs more, so don’t leave it there longer than you need to.
Gas furnaces don’t ice up, but make sure the intake and exhaust pipes outside a high-efficiency furnace aren’t blocked by snow or ice. A blocked vent shuts the furnace off for safety.
After an outage: how do I restart my system?
- Wait a few minutes after power returns. Many systems have a built-in delay.
- Check the breakers for the furnace or air handler and the outdoor unit.
- Make sure the furnace switch (it looks like a light switch) is on.
- Check the thermostat. Some lose their settings or need new batteries.
- If the system still won’t run, or a heat pump is iced and won’t clear, call.
When should I call?
- No heat, and the steps above don’t fix it.
- A heat pump encased in ice, or blowing cold air for long stretches.
- The furnace starts and shuts off repeatedly.
- You smell gas or a carbon monoxide alarm sounds. Leave first, then call NW Natural or 911 from outside.
No-heat calls are treated as urgent. Call 503-667-7594, or book a repair. Read more about heat pump repair and furnace repair.
Ready when you are
Book a repair, maintenance visit or estimate online, with arrival windows of 8am to 12pm or 1pm to 5pm. No heat or no cooling? Call and we treat it as urgent.
Common questions
Should I cover my heat pump in an ice storm?
No. Covering a heat pump that's running blocks airflow. Keep it clear, make sure gutters don't drip on it, and let defrost mode work.
My heat pump is encased in ice. What do I do?
Don't chip or pour boiling water on it. Switch the thermostat to emergency heat if you have it, and call for service.
What should I do after the power comes back?
Give the system a few minutes. If it doesn't start, check the breakers and the furnace switch, reset the thermostat, and call if it still won't run.
Can my furnace run on a generator?
Many gas and propane furnaces can, with a properly sized generator and the right connection. A licensed electrician handles the hookup.